Blade Appearance and Symptoms Probable Causes Remedy
Uneven Wear - frequent Blade Change aillance international Poor roll surface.
aillance international Damaged or dirty blade     holder.
aillance international Deposits.
aillance international Use more flexible blade.
aillance international Clean, repair or replace     holder.
aillance international Use abrasive blade.
Uneven Wear - frequent Blade Change
Excessive Wear in Center of Blade, or at Ends aillance international Doctor not machined to     match roll crown.
aillance international Old doctor sagging     into/away from roll.
aillance international Refit and shim holder to     doctor back as necessary.     (Return new doctor for     replaning if mismatch is     excessive.)
aillance international Replace old, sagging     doctor.
Excessive Wear in Center of Blade, or at Ends
Excessive Wear on one End aillance international Doctor misaligned - not     parallel to roll axis. aillance international Shim, or move bearings and     brackets as necessary to     align doctor parallel to axis     of roll
Excessive Wear on one End
Even Wea But Rough Edge aillance international Deposits on roll.
aillance international Excessive pressure on     blade.
aillance international Blade material too hard.
aillance international Use abrasive blade as     required.
aillance international Reduce pressure.
aillance international Use softer blade.
Even Wea But Rough Edge
Excessive Wear in Sheet Run aillance international Deposits left on roll by     sheet. aillance international Use abrasive blade as     required.
aillance international Trim blade edges     frequently.
aillance international Use end slotted blades to     prevent build-up of     excessive pressure on roll     ends.
Excessive Wear in Sheet Run
Excessive Wear Outside Sheet aillance international Sheet lubricates roll aillance international Slot blade ends to relieve     pressure.
Excessive Wear Outside Sheet
Localized Pitting aillance international Blade attacked by
aillance international Electrostatic discharge
aillance international Electrolysis,
    Heat
aillance international Insulate doctor from     machine frame or use     non-metallic blade.
Localized Pitting
Blade Develops Feathered Edge aillance international Blade material too soft.
aillance international Excessive pressure.
aillance international Blade angle too flat.
aillance international Use harder blade.
aillance international Reduce pressure.
aillance international Move bearings or     brackets to increase     angle. Check for correct     angle with gauge.
Blade Develops Feathered Edge
Hooks on Blade Outside Roll Surface aillance international Blade overhangs roll
aillance international Not centered.
aillance international Too long.
aillance international Not oscillating properly.
aillance international Center blade
aillance international Trim Length.
aillance international Adjust oscillation stroke.
Hooks on Blade Outside Roll Surface
Dent in Blade Edge aillance international Blade caught scab on roll at     start-up. (Most common on     old dryers.) aillance international Change blade and     remove scab.
Dent in Blade Edge
Increasing Pressure Increases Deflection aillance international Blade pressure changed     after initial     wear-in;     (opens blade tip to trap     particles and lift blade -     may cause wrap. aillance international Reduce blade pressure or     change blade.
Increasing Pressure Increases Deflection
 
 
aillance international Doctor Blades Systems
aillance international Types of Blade
aillance international Blade Holder
aillance international Doctor Blade Recommendations
aillance international Doctor Blade Wear Guide
aillance international Doctor & Doctor Blade Safety