Paper Mill Machinery |
Alliance International is a leading Pulp and Paper Mill Machinery supplier. We are leading suppliers of consumables, components, assemblies and new and used paper machinery. |
Paper Machine Vaccum Pump |
We supply high quality paper machine vaccum pump. Details are given below. |
|
Vaccum Pumps Selection Data Sheet for Garuda
"GXl - Liquid Ring Vacuum Pump |
|
Suction Capacity of Air in M3 / hr & Power Input to the pump in kw |
Model no |
Speed Rpm |
Moter kw |
Low Vaccum |
Meadium Vaccum |
High Vaccum |
Seal Water Approx |
|
|
100 Kw |
Kw |
200 mm |
kw |
400mm |
kw |
500 mm |
kw |
600 mm |
kw |
LMP |
GXL 400 |
960 |
15 |
560 |
7.5 |
550 |
8.5 |
500 |
10.5 |
500 |
10.5 |
450 |
10.5 |
18-15 |
1150 |
18.5 |
650 |
11.5 |
650 |
11.5 |
600 |
13.5 |
600 |
13.5 |
575 |
13.5 |
1350 |
22 |
775 |
14 |
775 |
14.5 |
700 |
18 |
700 |
18 |
650 |
18 |
1470 |
30 |
795 |
18 |
780 |
19.5 |
740 |
22.5 |
735 |
22.5 |
670 |
22.5 |
|
GXL 700 |
890 |
30 |
1025 |
12.5 |
1025 |
15 |
975 |
18 |
950 |
1 |
800 |
18.5 |
25-68 |
980 |
30 |
1125 |
15 |
1125 |
15.5 |
1075 |
21 |
1050 |
22 |
92 |
22 |
1070 |
37 |
1200 |
17 |
1200 |
22.5 |
1150 |
24 |
1150 |
26 |
100 |
26 |
1450 |
45 |
1285 |
19 |
1265 |
27 |
1245 |
28 |
1210 |
29 |
110 |
31 |
|
GXL 1000 |
690 |
37 |
1550 |
19 |
1550 |
22 |
1450 |
28 |
1375 |
29 |
127 |
29 |
42-95 |
770 |
45 |
1700 |
26 |
1700 |
28 |
1600 |
33 |
1550 |
35 |
1425 |
35 |
820 |
45 |
1800 |
30 |
1800 |
32 |
1700 |
36 |
1650 |
39 |
155 |
39 |
880 |
55 |
1920 |
33 |
1920 |
40 |
1800 |
44 |
1795 |
44 |
1595 |
44 |
|
GXL 2000 |
500 |
75 |
3020 |
38 |
3020 |
42 |
2800 |
53 |
2700 |
53 |
2400 |
55 |
68-180 |
500 |
75 |
3300 |
46 |
3300 |
52 |
3100 |
59 |
3100 |
59 |
2700 |
63 |
600 |
90 |
3650 |
48 |
3650 |
59 |
3400 |
69 |
3300 |
69 |
3000 |
71 |
640 |
110 |
3750 |
62 |
3750 |
70 |
3650 |
81 |
3500 |
84 |
3225 |
84 |
|
GXL 3000 |
400 |
110 |
4300 |
38 |
4200 |
60 |
4075 |
80 |
4075 |
80 |
3500 |
800 |
84-200 |
460 |
110 |
4700 |
58 |
4700 |
70 |
4575 |
90 |
4800 |
105 |
4000 |
105 |
500 |
132 |
5100 |
72 |
5000 |
90 |
5000 |
105 |
4800 |
105 |
4400 |
105 |
525 |
132 |
5250 |
85 |
5250 |
95 |
5150 |
108 |
4975 |
108 |
4450 |
112 |
|
GXL 4000 |
325 |
132 |
5650 |
55 |
5600 |
75 |
5000 |
108 |
4950 |
108 |
4500 |
105 |
116-225 |
360 |
150 |
6250 |
68 |
6200 |
90 |
5800 |
113 |
5600 |
113 |
5100 |
105 |
400 |
160 |
6900 |
90 |
6800 |
120 |
6500 |
131 |
6200 |
131 |
5700 |
135 |
450 |
200 |
7900 |
104 |
7800 |
142 |
7300 |
164 |
7000 |
164 |
6500 |
157 |
|
GXL 6000 |
280 |
200 |
940 |
114 |
9300 |
129 |
8850 |
164 |
8300 |
165 |
7100 |
165 |
150-336 |
300 |
220 |
10100 |
134 |
10000 |
149 |
9500 |
174 |
8800 |
174 |
7000 |
174 |
330 |
250 |
11100 |
174 |
10950 |
184 |
10500 |
204 |
9100 |
207 |
8600 |
214 |
|
Gardner Denver Nash is Registered Trademark of its Respective Origin Manufacturing Vacuum Pump & Other Products. None of which have any affiliation with M/s. Dhanvati Industries, M/s. Garuda Vacuum & Refining Technology Pvt. Ltd. or Garuda brand Vacuum Pumps.
Notes:
Tolerance on Performance Data : Suction Volume & Power Input + 5%.
Performance Data is based on inlet water temp at 30 c & Inlet pressure of 1kg/cm.
For water ring compressor please request for further details.
Design improvements are a continuous process, hence above data is subject to change without any notice.
Handling atmospheric air(50% R.H.) at sea level.(Barometric 760 mm HG).
Above Figures are for Guideline only. Actual figures please ask for PERFORMANCE CURVE.
|